Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 8.00/Piece
Request Sample
|
Suppliers with verified business licenses
Technical Parameter | |||||||||
Product Model | CDKG-S-15, CDKG-S-30, CDKG-S-45, CDKG-S-60, CDKG-S-75, CDKG-S-100, CDKG-S-120, CDKG-S-240, CDKG-S-480 |
||||||||
Output voltage | 15~100W | 120W | 240W | 480W | |||||
Scope AC | 100~240V | 100~120V/200~240V Switch selection |
100~240V | 100~120V/200~240V Switch selection |
|||||
Output voltage tolerance DC | Voltage value | 15~75W | 100~120W | 240~480W | * | ||||
5V ± 1% | - | * | * | * | |||||
12V ± 1% | - | - | * | * | |||||
15V ± 1% | - | - | * | * | |||||
24V ± 1% | - | - | - | - | |||||
48V ± 1% | * | * | - | - | |||||
Each specification can only output one set of corresponding voltages, with "-" indicating the conventional preferred voltage. Special voltage levels require protocol customization. | |||||||||
Overload protection | 110~200% | ||||||||
Overvoltage protection | 110~140% | ||||||||
Temperature protection | 100 ± 5ºC | ||||||||
Output circuit | Single channel output | ||||||||
Output voltage regulation range | ± 10% | ||||||||
Pressurization | Input and housing: 1.5KVAC/1min, Output and housing: 0.5KVAC/1min | ||||||||
Cooling method | Natural air cooling | ||||||||
Work environment | Working temperature: -10 ºC+55 ºC, relative humidity 20% -90% RH |
Product model | Output power | Output voltage |
CDKG-S | ||
15:15W 30:30W 45:45W ... 480:480W |
05:5V 12:12V 15:15V 24:24V 48:48V |