Basic Info.

Model NO.
GW4-12/18/24
Operation
Manual
Grounding Mode
Grounding
Movement Mode
Plug-in Type
Number of Poles
Three Pole
Grounding
Double Ground
Series
Three
Run
Turn the Horizontal
Switching Mode
Single Throw-in
Common Model
YR
Certification
CE, CCC
Brand
DELIXI
Transport Package
as Customer′s Requirement
Specification
40kg
Trademark
Delixi electric
Origin
China
Production Capacity
50000/Piece/Year

Product Description

1. Meaning of type


Outdoor AC Disconnector Switch for High Voltage

2. Main purposes and application range

The outdoor ac disconnect switch is an outdoor high-voltage electrical appliance, is applicable to electric power lines of rated voltage up to 15kV and rated frequency of 50Hz, this outdoor ac unit switch is used to break and make the live circuitries without loads.

3. Executive standards

a.GB1985-89 Alternating current high-voltage disconnectors and earthing switches

b.lEC129 Alternating current disconnectors and earthing switches

4. Technical data

Item Unit Value
Max.working voltage kV 12  18  24
Rated voltage KV 10  15  20
Rafed
insulaling
level
a)1 min power frequency withstand voltage(valid value) To earth kV 42
Inlerruple kV 49
b)Rated thunder impulse withstand voltage(peak) To earth kV 75
Interrupler kV 85
Rated frequency Hz 50
Rated current A 200  400 630  1250
Rated short time withstand current KA 12.5  16  20  31.5
Ration peak withstand current KA 31.5  40  50  80
Rated short-circuit duration Main/earthing blade $ 4/2
Raled terminal mechanical load Honzontal portrait N 500
Horizontal transverse N 250
Vertical force N 300
Creepage distance mm 300   372 450 558  600  744
Mechanical life Times 10000
Electromotor operating me chanism Type   CT-X
Motor vonage V AC380 AC220 DC220 DC110
Control loop voltage V AC380 AC220 DC220 DC110
Switch-offf/on time $ 7±1
Manual operating mechanism Type   CS11 CS8-6D
Electromagnetic lock voltage V AC220,DC220 DC110
Weight of poduc Wthout earthing kg 45  100  160
Single earthing kg 65  120  180
Double earthing kg 80  140  200