• Metal Enclosed Sf6 Gis Switchgear Cdrm6-12/24kv
  • Metal Enclosed Sf6 Gis Switchgear Cdrm6-12/24kv
  • Metal Enclosed Sf6 Gis Switchgear Cdrm6-12/24kv
  • Metal Enclosed Sf6 Gis Switchgear Cdrm6-12/24kv
  • Metal Enclosed Sf6 Gis Switchgear Cdrm6-12/24kv
  • Metal Enclosed Sf6 Gis Switchgear Cdrm6-12/24kv

Metal Enclosed Sf6 Gis Switchgear Cdrm6-12/24kv

Certification: CCC
Shell Material: Steel Plate
Voltage Level: Medium Voltage
Installation: Removable
Structure: Cabinet
Current: AC
Samples:
US$ 9999/pieces 1 pieces(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
CDRM6
Transport Package
as Customer′s Requirement
Specification
sf6
Trademark
Delixi electric
Origin
Zhejiang, China
Production Capacity
50000/Piece/Year

Product Description

The CDRM6 series GIS is new generated small size modular switch equipment have modular structure, such as the unit type and box type. Each module has its own functions and metal enclosure, and they can extend at the right and left side arbitrarily. According to different design scheme, they can combine arbitrarily to complete different distribution work. When the number of the configuration modules is more than 6 modules, the switchgear should be connected through extending busbar, which achieve semi­ modularized structure. All gas tanks are adopted 3mm imported stainless steel sheets, which is welded automatically by automatic rotary platform and Japanese Panasonic welding machine to ensure the leak proofness of the tank. The tank is filled with SF6 gas, and the load switch, earthing switch etc. switch moving parts and the busbar are sealed in the stainless steel tank, which greatly improve the safety performance electric products and the IP of GIS enclosure is reached to 67. The bottom of the tank is installed with explosion-proof membrane. It can prevent people from the injury effectively, also no damage occurs in cable, switch station and other switch equipment.

 

The 24kV switchgear is the top GIS ring main unit. The material and manufacture process are under strict control. The necessary materials such as main epoxy components, plastic parts and silicone rubber components are supplied from famous international company. All of the materials must be test by helium mass spectrometer leak detector and X-ray nondestructive flaw detector, as well as relative partial discharge test and voltage test, to ensure all the components are reliable. During the assembling process, mechanical characteristic test instrument imported from Germany is employed to accurately test the electric & mechanical performance, for example, breaking-closing switch period, stroke and speed, thus to guarantee the producing quality of the production. With the advantages of the compact structure, whole sealing, fully insulation, long life, free maintenance, small size and safety, CDRM6 series GIS is widely used in industrial and civil cable ring net and power supply terminal, and it is suitable for small-size secondary power distribution station, switching station .industrial and mining enterprises, airport, railway, commercial district, buildings, high ways and the places of severe environment.


Characteristics

The metal enclosed switchgear uses SF6 gas as arc-extinguishing and insulating medium. It adopots fully-sealed and fully- insulating structure. Busbar, switches and live parts are completely sealed in stainless-steel case, which is filled with SF6 gas of 1.4 bar pressure. Its protection rating can reach IP67. The whole switch decive is protected from external environment. Even under extreme case like immersed in water for short time, it can operate normally. This product is maintenance free for life long. This series GIS are provided with five interlocking decives for safeguard to keep the operators and equipments from breakdown which is caused by manual misoperation. All switchgears have reliable pressure relief decives, which guarantees the safety of operators under extreme conditions. Switchgears can be classified as fixed unit combination and extensible unit combination. The incoming and outgoing lines are installed at the front. Line installation at sides are also available. The switchgear is of small size, which makes mounting easy. It can be installed in places of small space and bad environment. Automatic, remote-controlling, monitoring decives can be installed according to customized requests


Main features

The switch cabinet is kept from the influence of bad environment, such as condensation, rime, salt mist, etc. All HV live parts and switch components are fully sealed in SF6 gas case. It is with features of compact structure, small size, light weight, completely insulation. Modularization and module combination can make different combination of main wiring. The circuit adopts silicone rubber connectors to make HV components connection and switchgear extension possible. It can be combined with HV monitor unit, integrated digital circuit breakers and overcurrent protective relay. The switchgear is provied with waterproof feature and long lifespan. Maintenance free will reduce operation cost, which meet the requests of distribution network automated upgrade.


Technical parameters

Item Unit C module
load switch
F module
composite
apparatus
V module CB module
Vacuum switch Disconnecting/
earthing switch
Vaxuum circuit
breaker
Disconnecting/
earthing switch
Rated voltage KV 12/24 12/24 12/24 12/24 12/24 12/24
Power frequency withstand voltage KV 42/65 42/65 42/65 42/65 42/65 42/65
Lighting impulse wihstand voltage KV 75/125 75/125 75/125 75/125 75/125 75/125
Rated current A 630/630 Lable 1 630/630   1250/800  
Rated transfer current A   1700/1500        
Breaking capacity A            
Closed loop breaking current A 630/630          
Cable charging breaking current A 10/16          
5% Rated active power load breaking current A 315.5/31.5          
Earthing fault breaking current A 200/150          
Cable charging breaking current of ground fault A 115/87          
Short circuit breaking current KA   Lable 2 25/16      
Closing capatity KA 63/52.5 Lable 2 50/40 50/40 25(20)Lable 3  
Short time withstand current 2S KA 25/25       25(50)Lable 3 63/50
Short time with stand Current 3S KA 20/20   25/16 25/16    
Mechanical life   3000 3000 10000 2000 25(20)Lable 3 25/20
Box stainless steel thickness mm     3.0   10000 2000
 
 
IP SF6 gas cell IP 67 Seal test
Fuse canister IP 67 Gas leakage rate w 0.25%
Switch cabinet IP3XIP4X
 
  • Lable 1: It depends on rated current value of fuse
  • Lable 2: Limited to high voltage fuse
  • Lable 3: The number in parentheses is the reference of CDRM6 at 24kv system

CDRM6-12/24 senes cabinet according to following standard design and manufacture:

IEC60265 IEC60298 IEC60420
IEC60265 IEC60298 IEC60420

Chinese national Industrial Standards:

GB/T11022-1999 GB3804-2004 GB7354-1987
GB16926-1997 GB1985-1989 GB11023-1989
 

CDRM6-12/24 type extension module unit cabinet

Standard extension module

C Load switch module (Width=325mm)
De Cable connection module with grounding knife (Width=325mm)
D Cable connection module without grounding knife (Width=325mm)
F Load switch fuse combination electric module (Width=325mm)
V Vacuum switch module (Width=325mm)
SL Bus bar section switch module (load switch) (Width=325mm)
SvBr Bus bar section switch module (vacuum switch)  
  Sv always together with bus bar ascending module (Total width325mm)
M/PT Metering module 12KV (Width=696mm)
  Metering module 24KV (Width=900mm)
CP/DP Pt panel module ( with switch and without switch) (Width=500mm)
 

Note: A single CD RM 6-12/24 type module only can be put into use with extension plug, The thickness of single piece of the side plate is 23 mm

CDRM6-1 2/24 type s weight sheet(tne weight below not including the accessories)
Metal Enclosed Sf6 Gis Switchgear Cdrm6-12/24kvStandard combination
CDRM6 Ring/Plus (12/24) we offer standard combination as below:
Metal Enclosed Sf6 Gis Switchgear Cdrm6-12/24kv

Each module has the following configuration of aeration tank:
D tank configuration
See Standard configuration and features as shown in the configuration of"Without grounding cable connection module of knife"

C tank configuration
See Standard configuration and features as shown in the configuration of"Load switch"


F tank configuration
See Standard configuration and features as shown in the configuration of"oad switch fuse combination electric appliance"


V tank configuration
See Standard configuration and features as shown in the configuration of"Vacuum switch"


Standard combination provides the following configuration:
1 .Capacitive voltage indicator into the bushing
2.Install a chamber pressure gauge meter to monitor SF6 in every gas chamber
3.Lifting lug
4.Operating handle


Metal Enclosed Sf6 Gis Switchgear Cdrm6-12/24kvExtensible type combination
In the same SF6 gas insulation chamber, it is up to six modules can be configured. In order to meet this need, it can be reserved in each module extension head, and connected by bus connect or. As shown in figure
Metal Enclosed Sf6 Gis Switchgear Cdrm6-12/24kvThe structure and dimension
The structure and dimension of CDRM6-12/24 typeMetal Enclosed Sf6 Gis Switchgear Cdrm6-12/24kvStructure
The Structure of the Metal enclosed switchgear
The GIS consists of cabinet and gas sealed stainless steel tank. There is no welding part on the cabinet. They are assembled as a whole through bolts.
Metal Enclosed Sf6 Gis Switchgear Cdrm6-12/24kv
Metal Enclosed Sf6 Gis Switchgear Cdrm6-12/24kvMetal Enclosed Sf6 Gis Switchgear Cdrm6-12/24kv

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
1000000 USD
Plant Area
>2000 square meters