Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: MCB
Samples:
US$ 3.46/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
DZ47PLEY-63
Poles Number
1p+N
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Certification
CE, CB, CCC
Rated Working Voltage
230AC
Rated Working Current
6-63A
Rated Frequency
50Hz
Breaking Capacity (Ka)
32A and Below: 6ka; 40-63A: 4.5ka
Rated Residual Operating Current (Ma)
10, 30, 50, 75,100, 300
Overvoltage Protection Function (V)
(280+-14; 14) VAC
Transport Package
Carton
Trademark
DELIXI ELECTRIC
Origin
China
HS Code
8536200000
Production Capacity
2000000pieces/Month

Product Description

Delixi Dz47pley-63 "Phase Line + Neutral Line" Earth Leakage Circuit Breaker
Delixi Dz47pley-63 "Phase Line + Neutral Line" Earth Leakage Circuit Breaker
Delixi Dz47pley-63 "Phase Line + Neutral Line" Earth Leakage Circuit Breaker
Delixi Dz47pley-63 "Phase Line + Neutral Line" Earth Leakage Circuit Breaker
Delixi Dz47pley-63 "Phase Line + Neutral Line" Earth Leakage Circuit Breaker
Delixi Dz47pley-63 "Phase Line + Neutral Line" Earth Leakage Circuit Breaker


Delixi Dz47pley-63 "Phase Line + Neutral Line" Earth Leakage Circuit BreakerThe DZ47PLEY-63 series leakage protection circuit breaker (RCBO) has overload, short circuit, leakage protection, and isolation functions. The product has a small size and compact structure. When personal electric shock or power grid leakage current exceeds the specified value, the modified series of products can quickly cut off the fault current in a very short time, protecting the safety of personnel and electrical equipment. This series of products is suitable for infrequently switching on and off electrical devices and lighting circuits, especially for industrial and commercial lighting distribution systems.
 
Rated insulation voltage Ui (V) 500 Wiring terminal form U-shaped wiring terminal
Maximum working voltage Uemax 1P+N (V)  230AC Maximum wiring capacity Current level 6-63A: 25mm²
Rated short-circuit capacity Icn (IEC/EN61009-1) (A) 32A and below: 6kA;
40-63A: 4.5kA
Maximum limit torque Current level 6-63A: 2.5N. m
Rated impulse withstand voltage Uimp (1.2/50) (kV)  4 Electrical life 10000 times
Dielectric test voltage (kV) 2kV (50/60Hz, 1 minute) Mechanical life 20000 times
Isolation function Available Protection level (installed in the distribution box) IP40
Pollution level  Level 2 Thermal magnetic tripping characteristics C-type, D-type
Tripping form Thermal magnetic tripping Reference set temperature 30 ° C

Delixi Dz47pley-63 "Phase Line + Neutral Line" Earth Leakage Circuit BreakerDZ47PLEY-63 "Phase line + neutral line" earth leakage circuit breake
Product name Inlet type Trip curve Rated current Residual current Other function
DZ47PLEY-63   C 6    
Delixi Dz47pley-63 "Phase Line + Neutral Line" Earth Leakage Circuit Breaker Default: Top inlet
R: Bottom inlet
C: C type 6: 6A
10: 10A
16: 16A
20: 20A
25: 25A
32: 32A
40: 40A
50: 50A
63: 63A
*Default: 30mA
R10: 10mA
R50: 50mA
R75: 75mA
R1: 100mA
R3: 300mA
Default: AC type earth leakage protection, without overvoltage protection
G: AC type earth leakage protection, with overload protection

Note: The product can be assembled with accessories OF, SD, MSN, MV, MN, MVMN, FF, FS, MO (active), and MOWY (passive)

Delixi Dz47pley-63 "Phase Line + Neutral Line" Earth Leakage Circuit BreakerDelixi Dz47pley-63 "Phase Line + Neutral Line" Earth Leakage Circuit Breaker
Frequently Asked Question (FAQ)
1.How could I get a sample?
   A:Before we received the first order, please afford the sample cost and express fee. We will return the sample cost back to you within your first order.
2.Sample time?
   A:Existing items: Within 10 days.
3. Whether you could make our brand on your products?
   A:Yes. We can print your Logo on both the products and the packages if you can meet our MOQ.                          4. How to guarantee the quality of your products?